American Mini Splits

Solar Mini Splits™ ~ 800-603-6376

Home

SolAire Solar Mini Split

Solar A/C Spec Sheet

Installation Pictures #1

Installation Pictures #2

Installation Pictures #3

Installation Pictures #4

Mini Split Specifications

Inverter

Multi-Zone Mini Split

How Does It Work

What The Heck Is A KW?

ABC's Of Heat Pumps

Electrical Cost Per Hour

Electric Usage Formula

Tankless Water Heater

Mini Split Wall Bracket

Installation Guide

Company Profile

Customer Feedback

Media/Press

Contact

SOLAR MINI SPLIT
SOLAR MINI SPLIT
SOLAR COOLING & HEATING MINI SPLITS 12K*24K
SPECIFICATIONS



 

Model Refrigerating Capacity Heating Capacity Refrigerating Power / Heating Power Electrical Source Applicable Area(m2)  Electric Class
AMS-35GW 3500 btu's
3600 780/800 220 10-18 I Class
AMS-50LW 5000 btu's 5300 1200/1250 220 25-35 I Class
AMS-70LW 7000 btu's 7100 1700/1850 220 35-45 I Class
AMS-120LW 12000 btu's 12300 2700/2800 220 45-60 I Class

  AMS-180LW                      18,000 btu's
  AMS-240LW                      24,000 btu's
  AMS-350LW                      35,000 btu's
  AMS-420LW                      42,000 btu's

1. The installation is not limited by the location,
it can be installed in any location on exterior of structure not limited to wall or roof or ground mount as the solar panel is not large. 
 
2. Compared to normal air conditioner's each room can be heated and cooled individually.  

 
3. The refrigeration of our solar mini splits are R22/R410A(environmentally friendly).

5. Solar Mini Splits can save up to 50% or more of the electric usage.

6. The air conditioner normally operates between the temperatures -13 degree F and 122 degree F, If the temperature exceeds 122 degrees the compressor will shut down. When the temperature returns to normal,system will restore operation.

 Specific Technology Requirements
When the copper pipe is lengthened, the refrigerent requirements will need to be increased.
 

Model Electric Current(A) Power(W) Pressure(Mpa) Increased Length Quantity of Increased Refrigerant(G)
AMS-35GW 3.8~4.5 750~900 0.45~5.2 3.0~7.0 30~70
AMS-50LW 5.4~6.2 1200~1300 0.45~5.2 3.0~7.0 40~80
AMS-70LW 7.2~8.2 1600~1700 0.45~5.2 3.0~7.0 40~80
AMS-120LW 12.0~13.8 2700~2950 0.45~5.2 3.0~7.0 50~100

Outer Temperature/
Power(A)/Pressure(Mpa)
26?-27? 28?-29? 30?-31? 34?-35? 36?-37? 38?-39?
AMS-35GW 0.4Mpa/3.8A 0.42Mpa/3.8A 0.45Mpa/3.9A 0.48Mpa/4.0A 0.50Mpa/4.1A 0.525Mpa/4.2A
AMS-50LW 0.45Mpa/5.4A 0.47Mpa/5.5A 0.48Mpa/5.6A 0.50Mpa/5.8A 0.505Mpa/5.9A 0.51Mpa/6.2A
AMS-70LW 0.45Mpa/7.2A 0.47Mpa/7.4A 0.48Mpa/7.5A 0.50Mpa/7.7A 0.505Mpa/7.9A 0.51Mpa/8.2A
AMS-120LW 0.46Mpa/12.0A 0.48Mpa/12.4A 0.50Mpa/12.5A 0.51Mpa/13A 0.52Mpa/13.5A 0.55Mpa/13.8A

  SOLAR MINI SPLITS INSTALLATION PICTURES BELOW.

  Solar Air Conditioner
 
 
SOLAR COOLING & HEATING
DUCTLESS MINI SPLITS

SELL YOUR UNUSED ELECTRIC
TO YOUR UTILITY


 UL Approved
 R22
 Enviromental refrigeration R410 option
 Thin and slim design
 Warm startup(cold air prevention)
 Independent dehumidification
 Ultra-quiet design
 Elegant design
 Remote Control

Model AMS35GW AMS35GW
Name  
Function Cooling Heating Cooling Heating
Capacity (W) 3500 3600 3500 3600
Auxiliary Electric Heating Power Consumption(W) 600
Air Circulation (M3/H) 540 550
Humidifying Power(KG/H) 1.2 1.33
Noise (DB(A)) 46(Indoor) , 50(Outdoor)
Dimension(D*W*H,mm) 900X295X370 (Indoor) , 600X750X330 (Outdoor) , 850X90X590 (Solar Panel)
Net Weight (kg) 10 (Indoor) , 28 (Outdoor) , 10 (Solar Panel)
Power Supply 220V-230V/60HZ 220V-230V/60HZ 220V-230V/60HZ (with T1 R22)
Climate Type T1 T1 T3 (with 220V-230V/60HZR22)
Refrigerant R22/R410A R22/R410A
Load Capacity (20‘)) 114 pcs
Load Capacity (40’)) 228 pcs
 

Electric Consumed vs Solar ASR VS Normal AC

Hour Electricity Consumed for Normal AC Electricity Consumed for Solar  AC Electricity Saved
1 hour 1.3 kw 0.7 kw 0.6 kw
10 hours 13 kw 7 kw 6 kw
1 month
(10 hours as 1 day)
390 kw 210 kw 180 kw
2 months
(10 hours as 1 day)
780 kw 420 kw 360 kw
5 months
(10 hours as 1 day)
1950 kw 1050 kw 900 kw
2 years
(5 months as 1 year)
3900 kw 2100 kw 1800 kw
5 years
(5 months as 1 year)
9750 kw 5250 kw 4500 kw

 

Solar Air Conditioner
 

Split Type >> AMS-50GW


 

Model AMS50GW/A AMS50GW/AD
Name  
Function Cooling Heating Cooling Heating
Capacity (W) 5000 5300 5000 5300
Auxiliary Electric Heating Power Consumption(W) 1200
Air Circulation (M3/H) 650 800
Humidifying Power(KG/H) 1.84 2
Noise (DB(A)) 47(Indoor) ,50(Outdoor)
Dimension(D*W*H,mm) 1075X285X353 (Indoor),1000X385X705 (Outdoor),850X90X590 (Solar Panel)
Net Weight (kg) 15 (Indoor),36(Outdoor),10 (Solar Panel)
Power Supply 220V-230V/50HZ 220V-230V/50HZ 220V-230V/60HZ (with T1 R22)
Climate Type T1 T1 T3 (with 220V-230V/50HZR22)
Refrigerant R22 R22  R407C
Load Capacity (20‘) 100 pcs
Load Capacity (40’) 200 pcs

Electricity Consume of Solar AC VS Normal AC

Hour Electricity Consumed for Normal AC Electricity Consumed for Solar  AC Electricity Saved
1 hour 2.1 kw 1.2 kw 0.9 kw
10 hours 21 kw 12 kw 9 kw
1 month
(10 hours as 1 day)
630 kw 360 kw 270 kw
2 months
(10 hours as 1 day)
1260 kw 720 kw 540 kw
5 months
(10 hours as 1 day)
3150 kw 1800 kw 1350 kw
2 years
(5 months as 1 year)
6300 kw 3600 kw 2700 kw
5 years
(5 months as 1 year)
15750 kw 9000 kw 6750 kw
Solar Air Conditioner
 

Split Type >> AMS-70GW

 


 Reinforced refrigeration
 Thin and slim design
 Warm startup(cold air prevention)
 Independent dehumidification
 Ultra-quiet design
 Elegant design
 Conductor blowing design

Model AMS70GW/A   ,  AMS70GW/AD  ,  AMS70GW/A   ,  AMS70GW/AD
Name  
Function Cooling Heating
Capacity (W) 7000 7000
Auxiliary Electric Heating Power Consumption(W) 2000
Air Circulation (M3/H) 1200
Humidifying Power(KG/H) 2.3
Noise (DB(A)) 52 (Indoor) , 56 (Outdoor)
Dimension(D*W*H,mm) 1160X283X383  (Indoor) , 945X425X740 (Outdoor),850X90X590 (Solar Panel)
Net Weight (kg) 5  (Indoor) , 45(Outdoor), 10 (Solar Panel)
Power Supplyy 220V-230V/50HZ 220V-230V/50HZ 220V-230V/60HZ (with T1 R22)
Climate Type T1 T1 T3 (with 220V-230V/50HZR22)
Refrigerant R22 R22  R407C
Load Capacity (20‘) 90 pcs
Load Capacity (40’) 180 pcs

Electricity Consumed for Solar AC VS Normal AC

Hour Electricity Consumed for Normal AC Electricity Consumed for Solar  AC Electricity Saved
1 hour 3.5 kw 1.7 kw 1.8 kw
10 hours 35 kw 17 kw 18 kw
1 month
(10 hours as 1 day)
1050 kw 510 kw 540 kw
2 months
(10 hours as 1 day)
2100 kw 1020 kw 1080 kw
5 months
(10 hours as 1 day)
5250 kw 2550 kw 2700 kw
2 years
(5 months as 1 year)
10500 kw 5100 kw 5400 kw
5 years
(5 months as 1 year)
26250 kw 12750 kw 13500 kw
Solar Air Conditioner
 

Split Type >> AMS-100GW

 


 Reinforced refrigeration
 Thin and slim design
 Warm startup(cold air prevention)
 Independent dehumidification
 Ultra-quiet design
 Elegant design
 Conductor blowing design

Model AMS100GW
Name  
Function Cooling Heating
Capacity (W) 9700 9700
Auxiliary Electric Heating Power Consumption(W) 2000
Air Circulation (M3/H) 1522
Humidifying Power(KG/H) 3.0
Noise (DB(A)) 56(Indoor) ,64(Outdoor)
Dimension(D*W*H,mm) 1360X280X370 (Indoor) ,1080X468X1075 (Outdoor),850X90X590 (Solar Panel)
Net Weight 23(Indoor) ,64(Outdoor), 10 (Solar Panel)
Power Supplyy 220V-230V/50HZ 220V-230V/50HZ 220V-230V/60HZ (with T1 R22)
Climate Type T1 T1 T3 (with 220V-230V/50HZR22)
Refrigerant R22 R22  R407C
Load Capacity (20‘) 70 pcs
Load Capacity (40’) 140 pcs

Electricity Consumed for Solar AC VS Normal AC

Hour Electricity Consume of Normal AC Electricity Consume of Solar  AC Electricity Saved
1 hour 4.5 kw 2.2 kw 2.3 kw
10 hours 45 kw 22 kw 23 kw
1 month
(10 hours as 1 day)
1350 kw 660 kw 690 kw
2 months
(10 hours as 1 day)
2700 kw 1320 kw 1380 kw
5 months
(10 hours as 1 day)
6750 kw 3300 kw 3450 kw
2 years
(5 months as 1 year)
13500 kw 6600 kw 6900 kw
5 years
(5 months as 1 year)
33750 kw 16500 kw 17250 kw
Solar Air Conditioner
 

Split Type >> AMS-120GW

 


 Reinforced refrigeration
 Thin and slim design
 Warm startup(cold air prevention)
 Independent dehumidification
 Ultra-quiet design
 Elegant design
 Conductor blowing design

Model AMS120GW/A
Name  
Function Cooling Heating
Capacity (W) 12000 12000
Auxiliary Electric Heating Power Consumption(W) 2000
Air Circulation (M3/H) 2100
Humidifying Power(KG/H) 3.0
Noise (DB(A)) 60(Indoor) ,68(Outdoor)
Dimension(D*W*H,mm) 1360X280X370 (Indoor) ,1080X468X1075 (Outdoor),950X90X680  (Solar Panel)
Net Weight (kg) 60 (Indoor) ,94(Outdoor),13 (Solar Panel)
Power Supply 220V-230V/50HZ 220V-230V/50HZ 220V-230V/60HZ (with T1 R22)
Climate Type T1 T1 T3 (with 220V-230V/50HZR22)
Refrigerant R22 R22  R407C
Load Capacity (20‘) 60 pcs
Load Capacity (40’) 120 pcs

Electricity Consumed for Solar AC VS Normal AC

Hour Electricity Consumed for Normal AC Electricity Consumed for Solar  AC Electricity Saved
1 hour 5.5 kw 2.7 kw 2.8 kw
10 hours 55 kw 27 kw 28 kw
1 month
(10 hours as 1 day)
1650 kw 810 kw 840 kw
2 months
(10 hours as 1 day)
3300 kw 1620 kw 1680 kw
5 months
(10 hours as 1 day)
8250 kw 4050 kw 4200 kw
2 years
(5 months as 1 year)
16500 kw 8100 kw 8400 kw
5 years
(5 months as 1 year)
41250 kw 20250 kw 21000 kw

COOLING & HEATING ROOM BY ROOM